-
1 ток
ток м., питающий рельсовую цепь ж. Gleisspeisestrom mток м., протекающий через контакт м. Kontaktstrom mток м., вызванный волной перенапряжения Wellenstrom mток м. утечки эл. Ableitungsstrom m; эл. Abstrom m; Fehlerstrom m; Fehlstrom m; Isolationsstrom m; Kriechen n; Kriechstrom m; Leckstrom m; Streustrom m; Störstrom m; Verluststrom m -
2 ток
current
движение элеронов по проводнику. измеряется в амперах и обозначается буквой i. — the movement of electrons through а conductor. measured in amperes,and ist symbol is i.
- (нагрузка) — load
- автостабилизации — autostabilization current
-, большой — high current
-, вихревой — eddy current(s)
also called foucault currents, inducted in body.
- включения (реле) — (relay) pickup current
- выключения (реле) — (relay) dropout /tripping/ current
- высокого напряжения (в оборудовании) — high-voltage current
- высокого напряжения (в системе зажигания) — high-tension (нт) current
- высокой частоты — high-frequency (hf) current
- датчиха момента акселерометра — torque current. a torque current being а measure of the restoring torque.
-, двухфазный — two-phase current
-, зарядный (аккумулятора) — (battery) charge current
monitor dc ammeter for normal charge current on battery.
-, малый (слабый) — low current
- нагрузки — load current
- нагрузки (разрядки) аккумулятора, элемента — (battery) drain. current supplied by a battery or cell.
-, обратный — reverse current
-, отпускания (реле) — dropout current
- отрыва (реле,прерывателя) — dropout current
-, переменный — alternating current (ас), (ac)
электрический ток, периодически изменяющийся по силе и направлению, т.е. достигающий макс. значения в одном направлении, затем падающий до нуля, и снова достигающий макс. значения, но в противоположном направлении. — а flow of electricity which reaches maximum in one direetion, decreases to zero, then reverses itself and reaches maximum in the opposite direction. the cycle is repeated continuously.
-, постоянный — direct current (do),(dc)
эл. ток, не изменяющийся ни по силе, ни по направлению. — an essentially constant-value current that flows in only one direction.
-, потребляемый — current drawn /consumed/
-, потребляемый (параметр в технических данных, таблице) — current, current requirements
-, потребляемый к-л. нагрузкой — current drawn /consumed, taken/ by а load
- потребляемый от источника питания — current drawn (consumed, taken from power source, power source drain
-, пусковой — starting current
-, рабочий — operating current
-, разрядный (акк.) — discharge current, drain
- расходуемый источником питания — power source drain
-, световой — light-inducted current
ток, возникающий в датчике под воздействием светового потока.
- срабатывания реле — relay operating current
- срабатывания реле (в отличие от тока отпускания) — relay pickup current
-, трехфазный — three-phase current
ток, поступающий по трем проводникам, каждый являющийся обратным проводом для двух других. — а current delivered through three wires - each wire serving as the return for the other two.
-, трогания — pickup current
ток, вызывающий срабатывание электромагнитных устройств. — the current at which a magnetically-operated device starts to operate.
- удержания (реле) — holding current
sufficient current in the relay winding to keep the relay energized.
- утечки — leakage current
-, электрический — electric current
магнитные поля, создаваемые электротоком. агрегат переменного (постаянного) тока (напр., генератор) — magnetic fields created by electric currents. ас (dc) unit, ас (dc) generator
измеритель тока (нагрузки) — loadmeter
под т. — energized
не отсоединять проводки, если цепь находится под током (напряжением) — do not disconnect wiring when the system is energized.
под током (напряжением) — alive
генератор под током, напряжением. — generator is alive.
включать т. — switch on current
при включении тока автостабилизации, якорь соленоида вызывает срабатывание клапана. — а solenoid, when the autostabilization current is switched on, pushes the central armature against a valve.
держать под т. — energize, keep energized
do not energize the solenoid for more than 10 sec.
работать на переменном (постоянном) т. — be ас (dc) powered
работать на переменном т. частотой... гц и напряжением...вольт — operate at а supply of... hz,... volts ас, be powered by... hz, volt ас
работать на постоянном т. напряжением... вольт — operate at а supply of... volts dc, be powered by... volt dcРусско-английский сборник авиационно-технических терминов > ток
-
3 ток разгорания
1.3.10 ток разгорания (warm-up current): Увеличенный ток лампы после фазы пуска, обусловленный низким начальным напряжением на лампе и снижаемый от двойного значения расчетного тока лампы до значения, соответствующего наибольшему напряжению на лампе.
Источник: ГОСТ Р 53075-2008: Лампы металлогалогенные. Эксплуатационные требования оригинал документа
Русско-английский словарь нормативно-технической терминологии > ток разгорания
-
4 ток тлеющего разряда
ток тлеющего разряда
Ток, который протекает после пробоя, когда полное сопротивление цепи ограничивает разрядный ток до значения, меньшего, чем ток перехода тлеющего разряда в дуговой разряд (МСЭ-Т K.12).
[ http://www.iks-media.ru/glossary/index.html?glossid=2400324]Тематики
- электросвязь, основные понятия
EN
Русско-английский словарь нормативно-технической терминологии > ток тлеющего разряда
-
5 ток половинного значения
nelectr. HalbstromУниверсальный русско-немецкий словарь > ток половинного значения
-
6 номинальный кратковременно выдерживаемый ток, Icw
номинальный кратковременно выдерживаемый ток
Icw
Это значение кратковременно выдерживаемого тока, установленное для выключателя изготовителем в условиях испытаний по 8.3.6.2.
Для переменного тока — это действующее значение периодической составляющей ожидаемого тока короткого замыкания, который рассматривают как неизменный на протяжении определенного короткого времени.
Длительность прохождения Icw должна составлять по крайней мере 0,05 с. Предпочтительные значения: 0,05; 0,1; 0,25; 0,5; 1 с.
Номинальный кратковременно выдерживаемый ток должен быть не- ниже указанного в таблице 3.
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
кратковременный выдерживаемый ток (ток термической стойкости)
Iт
Ток, который выключатель должен пропускать во включенном положении в течение нормированного короткого промежутка времени при предписанных условиях применения и поведения
[ ГОСТ Р 52565-2006]
номинальный кратковременный выдерживаемый ток (ток термической стойкости) IT, кА
Ток, который цепь или коммутационный аппарат может выдержать во включенном положении в течение нормированного короткого промежутка времени при предписанных условиях применения и поведения.
[ ГОСТ Р 52726-2007]
номинальный кратковременный выдерживаемый выключателем ток является максимальным током (выраженным в кА), который должен выдерживать выключатель в положении с замкнутыми контактами на протяжении заданного времени. Номинальный кратковременный выдерживаемый ток равен номинальному току короткого замыкания при отключении. Стандартные значения промежутка времени равны 1 или 3 с.
[http://forca.ru/info/spravka/nominalnyi-kratkovremennyi-vyderzhivaemyi-vyklyuchatelem-tok.html]Тематики
- выключатель автоматический
- выключатель, переключатель
- высоковольтный аппарат, оборудование...
Синонимы
- кратковременный выдерживаемый ток
- номинальный кратковременный выдерживаемый выключателем ток
- ток термической стойкости
EN
Русско-английский словарь нормативно-технической терминологии > номинальный кратковременно выдерживаемый ток, Icw
-
7 остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
остаточный ток несущей
Ток несущей частоты, появляющийся на выходе преобразователя частоты аппаратуры системы передачи с ЧРК за счет неидеальной балансировки его балансного модулятора и конечного значения затухания на этой частоте в полосе затухания фильтра.
[ ГОСТ 22832-77]Тематики
Синонимы
EN
DE
FR
52. Остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
Остаточный ток несущей
D. Tragerrest
Е. Carrier leak
F. Residu du courant porteur
Ток несущей частоты, появляющийся на выходе преобразователя частоты аппаратуры системы передачи с ЧРК за счет неидеальной балансировки его балансного модулятора и конечного значения затухания на этой частоте в полосе затухания фильтра
Источник: ГОСТ 22832-77: Аппаратура систем передачи с частотным разделением каналов. Термины и определения оригинал документа
Русско-немецкий словарь нормативно-технической терминологии > остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
-
8 остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
остаточный ток несущей
Ток несущей частоты, появляющийся на выходе преобразователя частоты аппаратуры системы передачи с ЧРК за счет неидеальной балансировки его балансного модулятора и конечного значения затухания на этой частоте в полосе затухания фильтра.
[ ГОСТ 22832-77]Тематики
Синонимы
EN
DE
FR
52. Остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
Остаточный ток несущей
D. Tragerrest
Е. Carrier leak
F. Residu du courant porteur
Ток несущей частоты, появляющийся на выходе преобразователя частоты аппаратуры системы передачи с ЧРК за счет неидеальной балансировки его балансного модулятора и конечного значения затухания на этой частоте в полосе затухания фильтра
Источник: ГОСТ 22832-77: Аппаратура систем передачи с частотным разделением каналов. Термины и определения оригинал документа
Русско-французский словарь нормативно-технической терминологии > остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
-
9 Минимальные значения воздушных зазоров и путей утечки токов
- 5.3. Значение путей утечки (длина) зависит от вида изоляционного материала и формы изолирующей детали.
- 5.2. Значения воздушных зазоров указаны с одной стороны как расстояние между двумя активными элементами
- 5.1. Значения воздушных зазоров и путей утечки приведены в таблице D.1 в зависимости от номинального напряжения по изоляции и условного теплового тока
D.5. Минимальные значения воздушных зазоров и путей утечки
D.5.1. Значения воздушных зазоров и путей утечки приведены в таблице D.1 в зависимости от номинального напряжения по изоляции и условного теплового тока Itheустройства цепи управления.
D.5.2. Значения воздушных зазоров указаны с одной стороны как расстояние между двумя активными элементами (L - L) и, с другой стороны, - как расстояние между активным элементом и близлежащей проводящей деталью (L - А). Расстояние между активным элементом и элементом, связанным с «землей» (который не является частью близлежащего проводника), может быть указано соответственно расстоянию L - L для рассматриваемого напряжения.
D.5.3. Значение путей утечки (длина) зависит от вида изоляционного материала и формы изолирующей детали.
Графа а таблицы D.1:
1) Керамические материалы (стеатит, фарфор).
2) Другие изолирующие материалы, из которых выполнены ребра или другие вертикально расположенные поверхности, для которых экспериментально доказано, что они соответствуют электроизоляционным требованиям при использовании их при таких же значениях путей утечки, что и керамические материалы.
Примечание - Такими могут быть материалы, имеющие сравнительный индекс трекингостойкости, по крайней мере, 140 В, например материалы, полученные из фенольных смол методом литья.
Графа b таблицы D.1:
Все другие случаи.
Значения в таблице D.1 приведены в качестве справочных и могут рассматриваться как минимальные.
Таблица D.1. - Воздушные зазоры и пути утечки
Номинальное напряжение по изоляции Ui, В
Воздушный зазор, мм
Путь утечки, мм
а
b
Ui£ 60
2
3
2
3
60 < Ui £ 250
3
5
3
4
250 < Ui £ 400
4
6
4
6
400 < Ui £ 500
6
8
6
10
500 < Ui £ 690
6
8
6
12
690 < Ui £ 750, переменный ток
10
14
10
14
750 < Ui £ 1000, переменный ток
14
20
14
20
Примечания
1. Значения относятся к атмосферным условиям, определенным в 6.1.3.2. При более жестких условиях значения путей утечки должны, как минимум, соответствовать значениям, приведенным в графе b.
2. Когда воздушный зазор L - A больше соответствующей длины пути утечки, указанной в графе а или b, зазор не должен быть короче изолирующего промежутка между токоведущим элементом и близлежащим проводящим элементом.
Источник: ГОСТ Р 50030.5.1-2005: Аппаратура распределения и управления низковольтная. Часть 5. Аппараты и коммутационные элементы цепей управления. Глава 1. Электромеханические аппараты для цепей управления оригинал документа
Русско-немецкий словарь нормативно-технической терминологии > Минимальные значения воздушных зазоров и путей утечки токов
-
10 максимальный ток на контакт электрического соединителя
максимальный ток на контакт электрического соединителя
Ток, проходящий через один из контактов электрического соединителя, температура перегрева которого не превышает заданного значения при условии, что через остальные контакты соединителя проходит ток, не превышающий 10 % максимального значения для контакта заданного типоразмера
[ ГОСТ 21962-76]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > максимальный ток на контакт электрического соединителя
-
11 допустимый длительный ток кабеля (провода)
- current-carrying capacity of the cable
- current carrying capacity of the conductors
- current carrying capacity of the cable
- current carrying capacity
- ampere capacity
допустимый длительный ток кабеля (провода)
-
[Интент]
допустимый длительный ток (проводника)
Максимальный электрический ток, который проводник способен проводить в продолжительном режиме без превышения его установившейся температурой определённого значения.
Допустимый длительный ток является одной из основных характеристик проводника. Он представляет собой максимальный электрический ток, который проводник может проводить длительно (неделями, месяцами, годами) не перегреваясь. Значение допустимого длительного тока зависит от сечения проводника, материалов из которых выполнены проводник и его изоляция, способов монтажа проводника в электроустановке здания. Допустимый длительный ток проводника фактически является его номинальным током. В электроустановках зданий выполняют защиту проводников от сверхтоков, протекание которых по проводникам сопровождается их перегревом.
[ http://www.volt-m.ru/glossary/letter/%C4/view/11/]EN
current carrying capacity
maximum current a cable circuit (one or several conductors) can support resulting in a specified increase of the surface temperature of the conductor beyond the ambient temperature, not exceeding the maximum allowed operating temperature of the cable
[IEC 61156-1, ed. 3.0 (2007-06< size="2">)]FR
courant maximal admissible
courant maximal qu’un circuit de câble (un ou plusieurs conducteurs) peut supporter avec une augmentation spécifiée de la température de surface du conducteur au delà de la température ambiante, et ne dépassant pas la température maximale de fonctionnement autorisée du câble
[IEC 61156-1, ed. 3.0 (2007-06< size="2">)]Номинальный ток устройств защиты от короткого замыкания может превышать допустимый длительный ток кабеля.
[ ГОСТ Р 50571. 5-94 ( МЭК 364-4-43-77)]Допустимые длительные токи для проводов и кабелей, проложенных в коробах, а также в лотках пучками, должны приниматься...
[ПУЭ]Тематики
- кабели, провода...
- электроустановки
EN
- ampere capacity
- current carrying capacity
- current carrying capacity of the cable
- current carrying capacity of the conductors
- current-carrying capacity of the cable
FR
Русско-английский словарь нормативно-технической терминологии > допустимый длительный ток кабеля (провода)
-
12 допустимый длительный ток кабеля (провода)
допустимый длительный ток кабеля (провода)
-
[Интент]
допустимый длительный ток (проводника)
Максимальный электрический ток, который проводник способен проводить в продолжительном режиме без превышения его установившейся температурой определённого значения.
Допустимый длительный ток является одной из основных характеристик проводника. Он представляет собой максимальный электрический ток, который проводник может проводить длительно (неделями, месяцами, годами) не перегреваясь. Значение допустимого длительного тока зависит от сечения проводника, материалов из которых выполнены проводник и его изоляция, способов монтажа проводника в электроустановке здания. Допустимый длительный ток проводника фактически является его номинальным током. В электроустановках зданий выполняют защиту проводников от сверхтоков, протекание которых по проводникам сопровождается их перегревом.
[ http://www.volt-m.ru/glossary/letter/%C4/view/11/]EN
current carrying capacity
maximum current a cable circuit (one or several conductors) can support resulting in a specified increase of the surface temperature of the conductor beyond the ambient temperature, not exceeding the maximum allowed operating temperature of the cable
[IEC 61156-1, ed. 3.0 (2007-06< size="2">)]FR
courant maximal admissible
courant maximal qu’un circuit de câble (un ou plusieurs conducteurs) peut supporter avec une augmentation spécifiée de la température de surface du conducteur au delà de la température ambiante, et ne dépassant pas la température maximale de fonctionnement autorisée du câble
[IEC 61156-1, ed. 3.0 (2007-06< size="2">)]Номинальный ток устройств защиты от короткого замыкания может превышать допустимый длительный ток кабеля.
[ ГОСТ Р 50571. 5-94 ( МЭК 364-4-43-77)]Допустимые длительные токи для проводов и кабелей, проложенных в коробах, а также в лотках пучками, должны приниматься...
[ПУЭ]Тематики
- кабели, провода...
- электроустановки
EN
- ampere capacity
- current carrying capacity
- current carrying capacity of the cable
- current carrying capacity of the conductors
- current-carrying capacity of the cable
FR
Русско-французский словарь нормативно-технической терминологии > допустимый длительный ток кабеля (провода)
-
13 длительный допустимый ток
- Strombelastbarkeit, f
- Dauerstrombelastbarkeit, f
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Русско-немецкий словарь нормативно-технической терминологии > длительный допустимый ток
-
14 длительный допустимый ток
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Русско-английский словарь нормативно-технической терминологии > длительный допустимый ток
-
15 остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
остаточный ток несущей
Ток несущей частоты, появляющийся на выходе преобразователя частоты аппаратуры системы передачи с ЧРК за счет неидеальной балансировки его балансного модулятора и конечного значения затухания на этой частоте в полосе затухания фильтра.
[ ГОСТ 22832-77]Тематики
Синонимы
EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > остаточный ток несущей частоты аппаратуры системы передачи с ЧРК
-
16 длительный допустимый ток
- courant permanent admissible, m
- courant admissible, m
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Русско-французский словарь нормативно-технической терминологии > длительный допустимый ток
-
17 периодический ток
периодический ток
Электрический ток, мгновенные значения которого повторяются через равные интервалы времени в неизменной последовательности.
Примечание — Аналогично определяют периодические электрическое напряжение, электродвижущую силу, магнитный поток и т. д.
[ ГОСТ Р 52002-2003]Тематики
- электротехника, основные понятия
Синонимы
EN
Русско-английский словарь нормативно-технической терминологии > периодический ток
-
18 пульсирующий ток (не проходящий через нулевые значения)
пульсирующий ток (не проходящий через нулевые значения)
—
[Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > пульсирующий ток (не проходящий через нулевые значения)
-
19 критический ток
критический ток
Значение тока отключения менее значения номинального тока отключения, при котором время дуги значительно возрастает.
[ ГОСТ Р 52565-2006]
критический ток
[IEV number 551-17-20]EN
transition current
the mean direct current of a converter connection when the direct current(s) of the commutation group(s) become(s) intermittent when decreasing the current
[IEV number 551-17-20]FR
courant critique
valeur moyenne du courant continu d'un montage convertisseur au-dessous de laquelle le courant continu des groupes commutants devient intermittent, lorsqu'on fait décroître le courant
[IEV number 551-17-20]Тематики
- высоковольтный аппарат, оборудование...
- электротехника, основные понятия
EN
DE
FR
Русско-немецкий словарь нормативно-технической терминологии > критический ток
-
20 максимально допустимый импульсный ток коллектора
максимально допустимый импульсный ток коллектора
-
Обозначение
IК,и max
ICMmax
Примечание
Максимально допустимыми параметрами называются значения конкретных режимов биполярных транзисторов, которые не должны превышать при любых условиях эксплуатации и при которых обеспечивается заданная надежность.
Максимально допустимые импульсные параметры приводятся для заданной скважности и длительности импульсов.
Когда не возникает сомнений в том, что используемое буквенное обозначение относится к максимально допустимому параметру, можно опускать индекс "max".
[ ГОСТ 20003-74]Тематики
EN
DE
FR
69. Максимально допустимый импульсный ток коллектора
D. Maximal zulässiger Kollektorimpulsstrom
E. Maximum peak collector current
F. Courant de crête de collecteur maximal
IК,и max
-
Источник: ГОСТ 20003-74: Транзисторы биполярные. Термины, определения и буквенные обозначения параметров оригинал документа
Русско-немецкий словарь нормативно-технической терминологии > максимально допустимый импульсный ток коллектора
См. также в других словарях:
Ток (значения) — Ток направленное движение электрически заряженных частиц. Ток представитель рода семейства птиц носорогов. Африканский серый ток Красноклювый ток Малабарский ток Черноклювый ток Южный желтоклювый ток Ток река в Оренбургской… … Википедия
Ток (приток Самары) — Ток Характеристика Длина 306 км Площадь бассейна 5930 км² Бассейн Каспийское море Водоток Исток … Википедия
ТОК (группа) — У этого термина существуют и другие значения, см. Ток (значения). ТОК фото логотип группы и альбома Империя Основная информация Жанры heavy metal, hard rock … Википедия
Ток (приток Зеи) — У этого термина существуют и другие значения, см. Ток (значения). Ток Характеристика Длина 251 км Площадь бассейна 6420 км² Бассейн Тихий океан Бассейн рек Зея → Амур … Википедия
Ток (аэропорт) — У этого термина существуют и другие значения, см. Ток (значения). Аэропорт Ток Tok Airport[1] … Википедия
Ток (кавалерия) — У этого термина существуют и другие значения, см. Ток (значения). Бескрылый польский гусар. Пятка пики упирается в детально прорисованный ток. У гусара татарские стремена и пра … Википедия
Ток (биология) — У этого термина существуют и другие значения, см. Ток (значения). Ток (токование) явление, когда на ограниченном пространстве собираются самцы определенных видов и конкурируют между собой за внимание самок. Токовища формируются сезонно на… … Википедия
ток — ((continuous) current carrying capacity ampacity (US)): Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их… … Словарь-справочник терминов нормативно-технической документации
Ток-шоу (значения) — Ток шоу (англ. Talk show) типичная телевизионная программа. Другие значения Ток шоу: Talk Show (группа) Американская рок группа Talk Show (альбом The Go Go s) Альбом группы The Go Go s Talk Show (Красавцы) Эпизод сериал Красавцы Ток шоу с… … Википедия
ток смещения — величина, пропорциональная скорости изменения переменного электрического поля в диэлектрике или вакууме. Название «ток» связано с тем, что ток смещения порождает магнитное поле по тому же закону, что и ток проводимости. * * * ТОК СМЕЩЕНИЯ ТОК… … Энциклопедический словарь
Ток-писин — (неомеланезийский язык, новогвинейский пиджин, меланезийский пиджин) креолизовавшийся пиджин. Официальный язык Папуа Новой Гвинеи (наряду с английским и хири моту), основной рабочий язык парламента, провинциальной и местной администрации.… … Лингвистический энциклопедический словарь